{"product_id":"12-24v-adjustable-timer-relay-delay-on-delay-off","title":"12\/24V Adjustable Timer Relay - Delay ON \/ Delay OFF","description":"\u003cstyle\u003e\n  .atr1224-product {\n    --atr-ink:#111111;\n    --atr-line:#d9d9d9;\n    --atr-soft:#f7f7f7;\n    width:min(1300px,calc(100vw - 40px));\n    max-width:none;\n    margin:32px 0;\n    padding:0;\n    position:relative;\n    left:50%;\n    transform:translateX(-50%);\n    color:var(--atr-ink);\n    background:transparent;\n    font:16px\/1.62 Arial, Helvetica, sans-serif;\n  }\n  .atr1224-product *, .atr1224-product *::before, .atr1224-product *::after,\n  .atr1224-faq *, .atr1224-faq *::before, .atr1224-faq *::after { box-sizing:border-box; }\n  .atr1224-product .atr1224-article { background:transparent; }\n  .atr1224-product .atr1224-header {\n    padding:28px;\n    color:#111111;\n    background:#ffffff;\n    border:1px solid var(--atr-line);\n    border-radius:18px 18px 0 0;\n    border-bottom:0;\n  }\n  .atr1224-product .atr1224-eyebrow {\n    margin:0 0 8px;\n    color:#555555;\n    font-size:.78rem;\n    font-weight:bold;\n    letter-spacing:.13em;\n    text-transform:uppercase;\n  }\n  .atr1224-product h1 { max-width:760px; margin:0; font-size:2.1rem; line-height:1.15; letter-spacing:-.03em; }\n  .atr1224-product .atr1224-lead { max-width:790px; margin:18px 0 0; font-size:1.1rem; color:#333333; }\n  .atr1224-product .atr1224-content { padding:10px 42px 44px; border:1px solid var(--atr-line); border-top:0; border-radius:0 0 18px 18px; }\n  .atr1224-product .atr1224-section { padding:28px 0; border-bottom:1px solid var(--atr-line); }\n  .atr1224-product .atr1224-section:last-child { border:0; }\n  .atr1224-product h2 { margin:0 0 14px; color:#111111; font-size:1.65rem; line-height:1.2; letter-spacing:-.02em; }\n  .atr1224-product h3 { margin:0 0 8px; color:#111111; font-size:1.2rem; line-height:1.25; }\n  .atr1224-product p { margin:0 0 14px; font-size:1.04rem; }\n  .atr1224-product strong { color:#111111; }\n  .atr1224-product ul { margin:10px 0 0; padding-left:23px; }\n  .atr1224-product li { margin:6px 0; }\n  .atr1224-product .atr1224-key-points { display:grid; grid-template-columns:repeat(3,1fr); gap:12px; margin-top:22px; }\n  .atr1224-product .atr1224-key-points div { padding:16px; border:1px solid var(--atr-line); border-radius:16px; background:#ffffff; }\n  .atr1224-product .atr1224-key-points div:nth-child(even) { background:var(--atr-soft); }\n  .atr1224-product .atr1224-key-points strong { display:block; font-size:1.1rem; }\n  .atr1224-product .atr1224-howto { display:grid; grid-template-columns:minmax(230px,.9fr) minmax(280px,1.4fr); gap:28px; align-items:center; }\n  .atr1224-product .atr1224-zoomable { cursor:zoom-in; transition:opacity .15s ease; }\n  .atr1224-product .atr1224-zoomable:hover { opacity:.9; }\n  .atr1224-product figure { margin:0; }\n  .atr1224-product figure img { display:block; width:100%; height:auto; border:1px solid var(--atr-line); border-radius:12px; }\n  .atr1224-product figcaption { margin-top:10px; color:#333333; font-size:1.2rem; line-height:1.55; font-weight:500; }\n  .atr1224-product .atr1224-wiring img { width:65%; margin:0 auto; cursor:zoom-in; transition:opacity .15s ease; }\n  .atr1224-product .atr1224-wiring img:hover { opacity:.9; }\n  .atr1224-product .atr1224-wiring figcaption { text-align:center; }\n  .atr1224-lightbox-overlay { display:none; position:fixed; inset:0; z-index:9999; align-items:center; justify-content:center; padding:24px; background:rgba(0,0,0,.85); cursor:zoom-out; }\n  .atr1224-lightbox-overlay.is-open { display:flex; }\n  .atr1224-lightbox-overlay img { max-width:95vw; max-height:95vh; border-radius:10px; }\n  .atr1224-product .atr1224-callout { margin:18px 0 0; padding:14px 16px; border-left:4px solid #111111; background:var(--atr-soft); border-radius:0 12px 12px 0; }\n  .atr1224-product .atr1224-mode-grid { display:grid; grid-template-columns:repeat(2,minmax(0,1fr)); gap:14px; }\n  .atr1224-product .atr1224-mode { padding:18px; border:1px solid var(--atr-line); border-radius:16px; background:#ffffff; }\n  .atr1224-product .atr1224-mode--on { background:var(--atr-soft); }\n  .atr1224-product .atr1224-flow { margin:13px 0 0; padding:12px 14px; color:#111111; border:1px solid var(--atr-line); border-radius:10px; background:#ffffff; font-size:1.03rem; font-weight:bold; }\n  .atr1224-product .atr1224-table-wrap { overflow-x:auto; margin:22px 0 4px; }\n  .atr1224-product table { width:auto; max-width:560px; min-width:0; border-collapse:collapse; border:1px solid var(--atr-line); }\n  .atr1224-product th, .atr1224-product td { padding:12px 13px; border:1px solid var(--atr-line); text-align:left; vertical-align:middle; font-size:1.02rem; }\n  .atr1224-product th { color:#111111; background:#eeeeee; font-weight:800; font-size:1.02rem; letter-spacing:.01em; }\n  .atr1224-product tbody tr:nth-child(even) td { background:#f7f7f7; }\n  .atr1224-product .atr1224-mode-name { width:31%; color:#111111; font-weight:bold; }\n  .atr1224-product .atr1224-note { color:#666666; font-size:.91rem; }\n  .atr1224-product .atr1224-terminal-grid { display:grid; grid-template-columns:repeat(5,minmax(0,1fr)); gap:8px; margin-top:17px; }\n  .atr1224-product .atr1224-terminal { padding:12px 9px; border:1px solid var(--atr-line); border-radius:12px; background:var(--atr-soft); }\n  .atr1224-product .atr1224-terminal b { display:block; color:#111111; font-size:1.15rem; }\n  .atr1224-product .atr1224-terminal span { display:block; margin-top:3px; color:#555555; font-size:.81rem; line-height:1.3; }\n  .atr1224-product .atr1224-wiring { margin-top:20px; }\n  .atr1224-product .atr1224-warning { margin-top:16px; padding:15px 17px; border-left:4px solid #e5a029; background:#fff9ed; border-radius:0 12px 12px 0; }\n  .atr1224-specifications,\n  .atr1224-faq {\n    width:min(1300px,calc(100vw - 40px));\n    max-width:none;\n    position:relative;\n    left:50%;\n    transform:translateX(-50%);\n    color:#111111;\n    font:16px\/1.62 Arial, Helvetica, sans-serif;\n  }\n  .atr1224-specifications { margin:0 0 32px; padding:28px 42px 44px; border:1px solid #d9d9d9; border-radius:18px; }\n  .atr1224-specifications h2 { margin:0 0 14px; color:#111111; font-size:1.65rem; line-height:1.2; letter-spacing:-.02em; }\n  .atr1224-specifications p { margin:0 0 14px; font-size:1.04rem; color:#333333; }\n  .atr1224-specifications .atr1224-specs { display:grid; grid-template-columns:repeat(2,minmax(0,1fr)); gap:0 30px; }\n  .atr1224-specifications .atr1224-specs p { padding:11px 0; margin:0; border-bottom:1px solid #d9d9d9; }\n  .atr1224-faq { margin:0 0 32px; padding:0; }\n  .atr1224-faq h2 { margin:0 0 14px; color:#111111; font-size:1.5rem; line-height:1.2; letter-spacing:-.02em; }\n  .atr1224-faq details { margin:9px 0; border:1px solid #d9d9d9; border-radius:14px; }\n  .atr1224-faq summary { padding:13px 16px; color:#111111; cursor:pointer; font-weight:bold; }\n  .atr1224-faq .atr1224-answer { padding:0 16px 15px; }\n  .atr1224-faq .atr1224-answer p { margin:0; color:#333333; }\n  @media (max-width:700px) {\n    .atr1224-product,\n    .atr1224-specifications,\n    .atr1224-faq { width:calc(100vw - 24px); margin:0 0 24px; }\n    .atr1224-product .atr1224-header, .atr1224-product .atr1224-content { padding-left:22px; padding-right:22px; }\n    .atr1224-product h1 { font-size:1.85rem; }\n    .atr1224-product .atr1224-howto, .atr1224-product .atr1224-key-points, .atr1224-product .atr1224-mode-grid, .atr1224-specifications .atr1224-specs { grid-template-columns:1fr; }\n    .atr1224-product .atr1224-terminal-grid { grid-template-columns:repeat(2,minmax(0,1fr)); }\n    .atr1224-product .atr1224-terminal:last-child { grid-column:span 2; }\n    .atr1224-specifications { padding:24px 22px; }\n    .atr1224-product .atr1224-wiring img { width:100%; }\n  }\n\u003c\/style\u003e\n\u003cmain class=\"atr1224-product\"\u003e\n\u003carticle class=\"atr1224-article\"\u003e\u003cheader class=\"atr1224-header\"\u003e\n\u003cp class=\"atr1224-eyebrow\"\u003eATR1224 - Universal multi-timer relay\u003c\/p\u003e\n\u003ch1\u003e12\/24V Adjustable Timer Relay - Delay ON \/ Delay OFF - 30A at 12V\u003c\/h1\u003e\n\u003cp class=\"atr1224-lead\"\u003eOne compact adjustable timer relay for 12V and 24V DC systems. Set Delay ON or Delay OFF from 0.5 seconds to 6 hours. Rated up to \u003cstrong\u003e30A at 12V\u003c\/strong\u003e and \u003cstrong\u003e15A at 24V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/header\u003e\n\u003cdiv class=\"atr1224-content\"\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003eHow to set a 10-minute Delay OFF\u003c\/h2\u003e\n\u003cdiv class=\"atr1224-howto\"\u003e\n\u003cfigure\u003e\u003cimg class=\"atr1224-zoomable\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0852\/2275\/2597\/files\/exemple_how_to_set_10_minutes_delay_off.webp?v=1785257337\" alt=\"ATR1224 12\/24V adjustable timer relay: 10-minute Delay OFF setup example\" width=\"695\" height=\"789\" loading=\"lazy\"\u003e\n\u003cfigcaption\u003eExample: keep an engine cooling fan running for 10 minutes after ignition is switched off.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cdiv\u003e\n\u003ch3\u003eSimple set-up\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Set A to position 2.\u003c\/strong\u003e This selects \u003cstrong\u003eDelay OFF\u003c\/strong\u003e with a 0.5-10 minute range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Turn B fully clockwise.\u003c\/strong\u003e This sets the delay to approximately 10 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Wire the fan to terminal 87.\u003c\/strong\u003e Connect terminal 30 to a permanent fused positive supply, 85 to ground and 86 to the ignition-switched positive signal.\u003c\/p\u003e\n\u003cp\u003eWhen ignition is switched off, the fan stays powered for the selected 10 minutes, then turns off automatically. Terminal 87a is unused in this application.\u003c\/p\u003e\n\u003cdiv class=\"atr1224-callout\"\u003e\n\u003cstrong\u003eSet, test, fine-tune:\u003c\/strong\u003e choose the range with A, set B, test one full cycle, then make a small adjustment if needed.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003eWhat is it?\u003c\/h2\u003e\n\u003cp\u003eBAYWATT ATR1224 is a \u003cstrong\u003e12\/24V adjustable timer relay\u003c\/strong\u003e in a compact 5-pin SPDT automotive relay format. It combines a high-current changeover relay with an adjustable electronic timer, so you can customize how long a circuit waits before switching on or how long it remains powered after its trigger is removed.\u003c\/p\u003e\n\u003cp\u003eThis is one bi-voltage \u003cstrong\u003e12\/24V timer relay\u003c\/strong\u003e, not separate 12V and 24V references. Its switching capacity is clearly rated at \u003cstrong\u003e30A at 12V\u003c\/strong\u003e or \u003cstrong\u003e15A at 24V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv class=\"atr1224-key-points\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e12\/24V DC\u003c\/strong\u003eOne timer relay for either DC system.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e30A at 12V\u003c\/strong\u003e15A at 24V switching capacity.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDelay ON \/ OFF\u003c\/strong\u003eAdjustable from 0.5 sec to 6 hrs.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003eHow does the adjustable timer work?\u003c\/h2\u003e\n\u003cdiv class=\"atr1224-mode-grid\"\u003e\n\u003cdiv class=\"atr1224-mode atr1224-mode--off\"\u003e\n\u003ch3\u003eDelay OFF: power stays ON after trigger OFF\u003c\/h3\u003e\n\u003cp\u003eWhen terminal 86 receives a positive trigger, terminal 87 powers the load immediately. When the trigger disappears, the selected timer begins. Terminal 87 stays powered, then switches off at the end of the delay.\u003c\/p\u003e\n\u003cp class=\"atr1224-flow\"\u003eTrigger ON - 87 ON - trigger OFF - selected delay - 87 OFF\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-mode atr1224-mode--on\"\u003e\n\u003ch3\u003eDelay ON: wait before power turns ON\u003c\/h3\u003e\n\u003cp\u003eWhen terminal 86 receives a positive trigger, the timer starts. Terminal 87 remains off during the selected delay, then powers the load when the timer ends.\u003c\/p\u003e\n\u003cp class=\"atr1224-flow\"\u003eTrigger ON - selected delay - 87 ON\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-callout\"\u003e\n\u003cstrong\u003eUse terminal 87a intelligently:\u003c\/strong\u003e in a Delay ON application, 87a can power a red WAIT light while the timer is counting. When the timer ends, 87a switches off and 87 can power a green READY light and the instrument.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003eA. Time Range \/ B. Time Adjust\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e selects the mode and broad time range. \u003cstrong\u003eB\u003c\/strong\u003e adjusts the exact time within that range. Turn B counter-clockwise for the shortest delay and clockwise for the longest delay.\u003c\/p\u003e\n\u003cdiv class=\"atr1224-table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDelay mode\u003c\/th\u003e\n\u003cth\u003eA. Time range\u003c\/th\u003e\n\u003cth\u003eB. Time adjust\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"atr1224-mode-name\" rowspan=\"5\"\u003eDelay OFF\u003cbr\u003e\u003cspan class=\"atr1224-note\"\u003eOutput switches OFF after the trigger is removed\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003e0.5 - 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e5 - 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e0.5 - 10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e5 - 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e0.5 - 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"atr1224-mode-name\" rowspan=\"5\"\u003eDelay ON\u003cbr\u003e\u003cspan class=\"atr1224-note\"\u003eOutput switches ON after the trigger is applied\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e0.5 - 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5 - 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e0.5 - 10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e5 - 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e0.5 - 10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003e5-pin timer relay wiring diagram\u003c\/h2\u003e\n\u003cp\u003eUse conventional automotive relay terminals. Terminal 30 is the permanent fused positive supply, 85 is ground, 86 is the positive trigger, 87 is the normally open timed output, and 87a is the normally closed alternate output.\u003c\/p\u003e\n\u003cdiv class=\"atr1224-terminal-grid\"\u003e\n\u003cdiv class=\"atr1224-terminal\"\u003e\n\u003cb\u003e30\u003c\/b\u003e\u003cspan\u003ePermanent fused +12\/24V supply\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-terminal\"\u003e\n\u003cb\u003e85\u003c\/b\u003e\u003cspan\u003eNegative \/ ground\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-terminal\"\u003e\n\u003cb\u003e86\u003c\/b\u003e\u003cspan\u003ePositive trigger signal\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-terminal\"\u003e\n\u003cb\u003e87\u003c\/b\u003e\u003cspan\u003eNormally Open timed output\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-terminal\"\u003e\n\u003cb\u003e87a\u003c\/b\u003e\u003cspan\u003eNormally Closed alternate output\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"atr1224-wiring\"\u003e\u003cimg class=\"atr1224-zoomable\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0852\/2275\/2597\/files\/wiring_diagram_example.webp?v=1785257336\" alt=\"ATR1224 12\/24V adjustable timer relay wiring diagram: terminals 30, 85, 86, 87 and 87a\" width=\"1656\" height=\"798\" loading=\"lazy\"\u003e\n\u003cfigcaption\u003eUse a fuse matched to the cable and load. Terminal 30 must remain powered during a Delay OFF cycle.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/section\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eCustomize your own timer instead of using a fixed-delay relay. The ATR1224 suits boats, vans, RVs, 4x4s, trucks, agricultural machines and auxiliary DC equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEngine cooling fans and ventilation blowers\u003c\/li\u003e\n\u003cli\u003eDelayed instrument or accessory activation after ignition\u003c\/li\u003e\n\u003cli\u003eCabin, cockpit, deck and courtesy lights\u003c\/li\u003e\n\u003cli\u003eFresh-water, circulation and washdown pumps\u003c\/li\u003e\n\u003cli\u003eSolenoid valves, compressors and auxiliary motors\u003c\/li\u003e\n\u003cli\u003eSequential start-up to reduce peak current draw\u003c\/li\u003e\n\u003cli\u003eControl signal for a separate high-current relay or contactor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"atr1224-section\"\u003e\n\u003ch2\u003eMini screwdriver included: adjust gently\u003c\/h2\u003e\n\u003cp\u003eA mini flat screwdriver is included to reach the recessed A and B adjustments. Use the supplied screwdriver or a very thin flat blade.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDo not push hard on the potentiometer; turn it with light pressure only.\u003c\/li\u003e\n\u003cli\u003eDo not use a large screwdriver or a wide blade.\u003c\/li\u003e\n\u003cli\u003eWhen B reaches the end of its travel, stop. Never force it.\u003c\/li\u003e\n\u003cli\u003eSet A first, then set B and test the timer before final installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"atr1224-warning\"\u003e\n\u003cstrong\u003eElectrical safety:\u003c\/strong\u003e fuse terminal 30 correctly, disconnect power before changing wiring, and never connect terminals 87 and 87a together.\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/main\u003e\n\u003cdiv class=\"atr1224-faq\"\u003e\n\u003ch2\u003eQuestions \u0026amp; answers\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this relay work on 12V and 24V?\u003c\/summary\u003e\n\u003cdiv class=\"atr1224-answer\"\u003e\n\u003cp\u003eYes. This is one universal 12\/24V DC timer relay. Its rating is 30A at 12V and 15A at 24V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between Delay ON and Delay OFF?\u003c\/summary\u003e\n\u003cdiv class=\"atr1224-answer\"\u003e\n\u003cp\u003eDelay ON waits before powering terminal 87. Delay OFF powers terminal 87 immediately, then keeps it powered for the selected time after the trigger at terminal 86 disappears.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I set a 10-minute delay?\u003c\/summary\u003e\n\u003cdiv class=\"atr1224-answer\"\u003e\n\u003cp\u003eYes. For a 10-minute Delay OFF, set A to position 2 and turn B fully clockwise.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat can I use terminal 87a for?\u003c\/summary\u003e\n\u003cdiv class=\"atr1224-answer\"\u003e\n\u003cp\u003e87a is the normally closed output. In Delay ON mode, it can power a red WAIT light until terminal 87 switches on to power a green READY light and the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I connect a load above the relay rating?\u003c\/summary\u003e\n\u003cdiv class=\"atr1224-answer\"\u003e\n\u003cp\u003eNot directly. Use terminal 87 to control the coil of a correctly rated high-current relay, contactor or solenoid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy must terminal 30 be fused?\u003c\/summary\u003e\n\u003cdiv class=\"atr1224-answer\"\u003e\n\u003cp\u003eTerminal 30 is the main positive supply. Fuse it according to the cable size and load. It must stay powered while a Delay OFF timer is running.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atr1224-lightbox-overlay\" id=\"atr1224-lightbox\"\u003e\u003cimg alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003cdiv class=\"atr1224-specifications\"\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eThe essential technical data for the ATR1224 12\/24V adjustable timer relay.\u003c\/p\u003e\n\u003cdiv class=\"atr1224-specs\"\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12\/24V DC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching capacity:\u003c\/strong\u003e 30A at 12V \/ 15A at 24V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e Delay ON \/ Delay OFF\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTiming range:\u003c\/strong\u003e 0.5 second to 6 hours\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact type:\u003c\/strong\u003e 5-pin SPDT changeover\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTerminals:\u003c\/strong\u003e 30 \/ 85 \/ 86 \/ 87 \/ 87a\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Compact Mini ISO-style relay\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e Mini flat adjustment screwdriver\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BAYWATT","offers":[{"title":"Default Title","offer_id":54478105477461,"sku":"ATR1224","price":32.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0852\/2275\/2597\/files\/ATR1224.webp?v=1785263016","url":"https:\/\/www.baywatt.com\/products\/12-24v-adjustable-timer-relay-delay-on-delay-off","provider":"BAYWATT","version":"1.0","type":"link"}